User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 789 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1777
rfu-mute-with-
timeout
Event
Equipment
RFU TX Mute with
timeout
Warning
RFU Transmitter muted
by user.
Unmute the RFU transmitter or
wait for expiration of the
timeout.
1778
rfu-power-
decreased-due-to-
pa-temp
Alarm Equipment
RFU power decreased
due to PA temperature
Major
Defective RFU (the RFU
cannot transmit the
requested TX power).
1.
Replace RFU.
2.
Intermediate solution -
reduce TX power.
1780
mrmc-running-
script-deleted
Event
Equipment
MRMC running script is
deleted
Warning
New installed software
package does not include
the running MRMC radio
script
1.
Make sure the required
software package include
the running MRMC radio
script.
2.
Download and install the
correct software package.
1781
mrmc-running-
script-updated
Event
Equipment
MRMC running script is
updated
Warning
New installed software
package does has an
updated version of the
running MRMC radio
script
Reset the radio carrier to
reacquire the new updated
MRMC radio script
1782
radio-2_5gbps-
mismatch-
configuration
Alarm Equipment
2.5Gbps mismatch
configuration
Warning
The card can not function
outside of an ABC group
in 2.5Gbps mode.
Add the card to an ABC group,
or change the Slot Section to
1Gbps.
1783
remote-fault-
indication
Alarm Communication
Radio remote fault
indication (RFI)
Minor
1790
np-hw-failure
Alarm Equipment
Hardware failure
Critical
An internal hardware
failure has been detected
by the system.
Replace the card or unit