User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 783 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1732
power-supply-
radio-unit-cable-
short
Alarm Equipment
Power supply cable
short
Major
1.
Power is enabled but
consumption
reached the
threshold.
2.
Physical short at the
ETH cable.
1.
Check ETH cable and
connectors.
2.
Replace RIC (Radio
Interface Card)
3.
Replace RFU.
4.
If RFU connected with
optical cable, disable
power interface.
1733
synthesizer-
unlocked
Alarm Equipment
RFU synthesizer
unlocked
Major
At least one of the RFU
synthesizers is unlocked
5.
Replace RFU.
6.
In XPIC mode, replace
mate RFU as well.
1734
tx-level-out-of-
range
Alarm Equipment
RFU TX level out of
range
Minor
Defective RFU (the RFU
cannot transmit the
requested TX power)
1.
Replace RFU.
2.
Intermediate solution -
reduce TX power.
1735
tx-mute
Alarm Equipment
RFU TX Mute
Warning
RFU Transmitter muted
by user
Unmute the RFU transmitter
1736
unknown-rfu-type
Alarm Equipment
IDU SW does not
support this type of RFU
Major
IDC SW does not support
the RFU
Upgrade IDC SW
1737
card-extracted-
from-slot
Event
Equipment
Card was extracted from
slot
Warning
Card was extracted from
slot
NA
1738
card-failure
Alarm Equipment
Card is in Failure state
Major
Card is down as a result
of card failure
1.
Reset Card.
2.
Check if slot was disabled.