User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 655 of 825
Ceragon Proprietary and Confidential
Parameter
Input Type
Permitted Values Description
control-group
Variable
rp1
rp2
rp3
rp4
lag1
lag2
lag3
lag4
mc-abc1
mc-abc2
mc-abc3
mc-abc4
When the control group is an HSB
protection group (rp1 - rp-4), a LAG
(lag1 - lag4), or a Multi-Carrier ABC
group (mc-abc1 - mc-abc4), use this
parameter instead of the control-
interface parameter to identify the
group. The group must be defined
before you create the ABN entity.
Note
: Multi-Carrier ABC and HSP
protection are only relevant for IP-
20C and IP-20C-HP units.
vlan
Variable
untag
1 - 4094, except
4092 (reserved
for the default
management
service)
The VLAN on which messages are
transmitted (optional).
admin-state
Variable
isUp
isDown
Enter isUp to enable ABN monitoring
on the interface, or isDown to disable
ABN monitoring on the interface.
monitoring-interval
Number
1 - 20
The interval (in seconds) for which a
weighted average of the bandwidth
readings is calculated.
message-frequency
Variable
4-one-second -
sets message
frequency to 1
second
5-ten-seconds -
sets message
frequency to 10
seconds
6-one-minute -
sets message
frequency to 1
minute
How often messages are transmitted
when bandwidth is below the nominal
value.
holdoff-time
Number
10 - 29
The amount of time the system waits
when bandwidth degradation occurs,
before transmitting a message.
The following command creates an ABN entity with radio interface 1 as the
monitored interface and Ethernet port 1 as the control interface. It also specifies
to transmit bandwidth messages on VLAN 1: