Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1702
cable-short
Alarm Equipment
Cable short
Major
Physical short at the IF
cable
1.
Check IF cable and
connectors.
2.
Verify that the N-Type
connector inner pin is not
spliced.
3.
Replace RMC (Radio
Modem Card).
4.
Replace RFU.
1703
communication-
failure
Alarm Equipment
RFU communication
failure
Warning
3.
Defective IF cable.
4.
IF cable not
connected properly.
5.
Defective RMC
(Radio Modem Card).
6.
Defective RFU.
7.
RFU software
download in
progress.
1.
Check IF cable and
connectors.
2.
Verify that N-Type
connector inner pin is not
spliced.
3.
Replace RMC (Radio
Modem Card).
4.
Replace RFU.
For a high power RF Unit:
1.
Check BMA connector on
OCB
2.
Check BMA connector on
RFU.
1704
delay-calibration-
failure-1
Alarm Equipment
RFU delay calibration
failure 1
Warning
Defective RFU
1.
Reset the RMC (Radio
Modem Card) / RFU.
2.