907
license-violation-
alarm
Alarm Equipment
Activation key violation
Critical
The current configuration
does not match the
activation-key-enabled
feature set.
48 hours after an
"activation-key-violation"
alarm is raised, sanction
mode is activated in
which all alarms except
the activation key
violation alarm are
cleared and no new
alarms are raised.
1.
Get the list of features'
configurations that are
violated via the "activation
key information report".
2.
Install a new activation key
that allows the use of all
required features.
908
demo-license-
about-to-expire-
alarm
Alarm Equipment
Demo mode is about to
expire
Major
Demo mode allowed
period is about to end
within 10 days
Disable demo mode and install
a new valid activation key.
910
license-signature-
failed-alarm
Alarm Equipment
Activation key signature
failure
Major
Activation key validation
has failed due to invalid
product serial number
Replace the IDU
911
license-violation-
runtime-counter-
expired
Event
Equipment
Activation key violation
sanction is enforced
Major
913
license-bad-xml-
file-alarm
Alarm Equipment
Activation key
components are missing
or corrupted
Major
Essential internal
activation key
components are missing
or corrupted.
Reinstall software