User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 792 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2013
pwe3-tdm-port-s-
lof
Alarm Equipment
Loss Of Frame (LOF) on
TDM-LIC TDM port
Major
1.
Line is not properly
connected.
2.
External equipment
is faulty.
2014
pwe3-tdm-port-s-
lomf
Alarm Equipment
Loss Of Multi-Frame
(LOMF) on TDM-LIC
TDM port
Major
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
2015
pwe3-tdm-port-s-
loopback-alarm
Alarm Equipment
Loopback on TDM-LIC
TDM port
Warning
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
2016
pwe3-tdm-port-s-
los
Alarm Equipment
Loss Of Signal (LOS) on
TDM-LIC TDM port
Major
1.
Line is not properly
connected.
2.
Cable is faulty.
3.
External equipment
is faulty.
4.
Defective TDM-LIC.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
2017
pwe3-tdm-port-s-
rai
Alarm Equipment
Remote Alarm
Indication (RAI) on
TDM-LIC TDM port
Minor
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.