User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 312 of 825
Ceragon Proprietary and Confidential
7.3.3.3
Assigning Broadcast Policers
To assign a policer for broadcast traffic to a logical interface:
1 Select
Ethernet > Interfaces > Logical Interfaces
. The Logical Interfaces page
opens (
2 Select the interface in the Ethernet Logical Port Configuration table and click
Policers
. The Policers page opens. By default, the Policers page opens to the
Unicast Policer table (
3 Select
Broadcast Policer
. The Broadcast Policer table appears.
Figure 235: Logical Interfaces
–
Policers Page
–
Broadcast Policer
4 In the
Policer profile
field, select a profile from the policer profiles defined in
the system. The
Policer profile
drop-down list includes the ID and description
of all defined profiles.
5 In the
Broadcast admin
field, select
Enable
to enable policing on broadcast
traffic flows from the logical interface, or
Disable
to disable policing on
broadcast traffic flows from the logical interface.
6 Click
Apply
.
7.3.3.4
Assigning Ethertype Policers
You can define up to three policers per Ethertype value.
To assign a policer to an Ethertype:
1 Select
Ethernet > Interfaces > Logical Interfaces
. The Logical Interfaces page
opens (