User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 243 of 825
Ceragon Proprietary and Confidential
10 Enable payload encryption on the local unit by following the procedure
described in Step 9. Verify that on both the local and remote active units, the
link status returns to Up and user traffic is restored. In links using in-band
management, verify also that in-band management returns.
11 In a protected link, perform copy-to-mate, first on the remote and then on the
local unit. See Step 5 in
Configuring HSB Radio Protection
. After the copy-to-
mate operation, wait for both standby units to re-boot and verify that there
are no alarms.
Note:
The standby unit may have a
payload encryption failure
alarm for up to
about one minute after the unit is up and running.
12 In a protected link, remove the protection lockout, first on the remote and
Disabling Automatic Switchover to the Standby
13 Verify that there are no alarms on the link.
Note:
Any time payload encryption fails, the Operational status of the link is
Down until payload encryption is successfully restored.