Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
5100
mkey-mismatch
Alarm Equipment
Master key mismatch
cross over the link
Critical
Master Key was not set
correctly.
Verify the Master Key.
5101
mkey-no-exist
Alarm Equipment
No Master Key set,
default value used
Warning
Crypto module has been
enabled, but no Master
Key has been loaded.
Set the Master Key.
5102
general-
encryption-failure
Alarm Equipment
Payload Encryption
failure
Critical
1.
Radio LOF on Tx/Rx
direction.
2.
The session key does
not match across the
link.
3.
The AES admin
setting does not
match across the
link.
1.
Validate the MSE on both
sides of the link.
2.
Validate the session key on
both sides of the link.
3.
Validate the AES admin
setting on both sides of
the link.
5104
kep-initiated
Event
Equipment
Key Exchange Protocol
in progress, Traffic has
been blocked
Indeterminate
5105
kep-remote-
initiated
Event
Equipment
Key Exchange Protocol
initiated by remote side
Indeterminate
5107
bypass-self-test-
alarm
Alarm Equipment
FIPS Bypass Self-Test
failed
Critical
Disk failure
5108
post-fail-alarm
Alarm Equipment
Power On Self-Test
Failed
Critical
System failure
Reboot the unit.