User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 793 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2018
pwe3-tdm-port-s-
unexpected-signal-
alarm
Alarm Equipment
E1/DS1 Unexpected
signal on TDM-LIC TDM
port
Warning
1.
Port is disabled.
2.
Line is connected to
a disabled port.
1.
Enable relevant port.
2.
Disconnect cable from
relevant port.
2021
pwe3-pwc-s-ssm-
rx-changed
Event
Equipment
SSM received pattern
change was discovered
Warning
No action is required.
2022
pwe3-stm1oc3-s-
excessive-ber-
alarm
Alarm Equipment
Excessive BER on TDM-
LIC STM1/OC3 port
Major
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.
2023
pwe3-stm1oc3-s-
lof-alarm
Alarm Equipment
Loss Of Frame (LOF) on
TDM-LIC STM1/OC3
port
Major
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.
2024
pwe3-stm1oc3-s-
loopback-alarm
Alarm Equipment
Loopback on TDM-LIC
STM1/OC3 port
Warning
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.
2025
pwe3-stm1oc3-s-
los-alarm
Alarm Equipment
Loss Of Signal (LOS) on
TDM-LIC STM1/OC3
port
Critical
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.