User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 784 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1739
card-fpga-fw-not-
found
Alarm Equipment
FPGA Firmware file not
found
Critical
There is no FPGA file
found on the Main Board
for the card on the slot
NA
1740
card-fw-load-fail
Alarm Equipment
Download card
firmware has failed
Major
Firmware download was
unsuccessful.
1.
Reset Card.
2.
Download software
package.
3.
Try to insert another Card.
1741
card-inserted-to-
slot
Event
Equipment
Card was inserted to
slot
Warning
Card was inserted to slot
NA
1742
card-intermediate-
channel-failure
Alarm Equipment
Card is in
interconnection failure
state
Major
Card is down as a result
of card interconnection
failure
1.
Reset Card.
2.
Check if the slot was
disabled.
1743
card-missing
Alarm Equipment
Expected Card is missing
in slot
Major
1.
Card is missing.
2.
Expected Card Type
configured on empty
slot.
1.
Insert Expected Card.
2.
Clear Expected Card Type.
1744
card-not-
supported-for-slot
Alarm Equipment
This Card type is not
supported in this slot
Major
The card is not on the
Allowed Card Types list
for this slot.
1.
Reset.
2.
Insert Card belongs to
Allowed Card Types list.
1745
card-state-is-down
Event
Equipment
Card operational state is
Down
Indeterminate
Card state was change to
Down state
NA
1746
card-state-is-up
Event
Equipment
Card operational state is
Up
Indeterminate
Card state was change to
Up state
NA