User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 254 of 825
Ceragon Proprietary and Confidential
◦
To display reports in daily intervals, select
24 hours
.
Note:
To display the same parameters for a specific interval in a separate
page, select the interval in the Modem MSE PM table and click
View
.
Table 40: Modem MSE PMs
Parameter
Definition
Interval
For 24-hour intervals, displays the date of the interval. For 15-
minute intervals, displays the date and ending time of the interval.
Min MSE (dB)
Displays the minimum MSE in dB, measured during the interval. A
0 in this field and an X in the
Integrity
field may also indicate that
the modem was unlocked during the entire interval.
Max MSE (dB)
Displays the maximum MSE in dB, measured during the interval. A
0 in this field and an X in the
Integrity
field may also indicate that
the modem was unlocked.
Exceed threshold seconds
Displays the number of seconds the MSE exceeded the MSE PM
threshold during the interval. The MSE PM is configured in the
Radio Thresholds page. See
Configuring BER Thresholds and
Integrity
Indicates whether the values received at the time and date of the
measured interval are reliable. An X in the column indicates that
the values are not reliable due to a possible power surge or power
failure that occurred at that time. An X and a 0 value in the
Max
MSE
field may also indicate that the modem was unlocked.
To set the Modem MSE PM thresholds, click
Thresholds
. The Modem MSE
Thresholds Configuration
–
Edit Page opens. For each radio, specify the modem
MSE (Mean Square Error) threshold for calculating MSE Exceed Threshold
seconds, and click
Apply
.
Figure 188: Modem MSE Thresholds Configuration
–
Edit Page