User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 815 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
31005
Clock-source-
sharing-failure-
alarm
Alarm Equipment
Clock source sharing
cable unplugged
Critical
1.
Faulty coaxial cable
between master and
slave RFUs
2.
Mate does not exist
1.
Replace faulty coaxial
cable and reset Master
RFU.
2.
Replace faulty RFU.
31100
AMCC-
Incompatible-
radio-script-alarm
Alarm Communications
Radio script is
incompatible to AMCC
Critical
MRMC Script selected
does not support AMCC
Group type/subtype
Set AFR Script in both Agg1 &
Agg2 carriers
31101
AMCC-
Inconsistent-
MRMC-Script-
alarm
Alarm Communications
Inconsistent MRMC
script between
members
Critical
All members of a group
must be configured to
the same MRMC Script
Set the members to the
appropriate MRMC script
31102
AMCC-
Inconsistent-radio-
frequency-alarm
Alarm Communications
Inconsistent radio
frequency
Critical
Radio TX/RX frequency is
not identical on all AMCC
carriers
Set same radio TX/RX
frequency on all AMCC carriers
31103
AMCC-Failed-To-
Load-Alarm
Alarm Communications
Agg 1 failed Bring-up
procedure
Critical
Agg1 did not complete
Bring-up successfully
Drop both Agg1 & Agg2 into
single carrier mode (Pre-Init)
31104
AMCC-Invalid-
ACM-
Configuration-
alarm
Alarm Communications
Invalid ACM
configuration
Critical
AMCC member have
been set to fixed profile
Set AMCC member to adaptive
ACM profiles