Table 39: Modem BER (Aggregate) PMs
Parameter
Definition
Interval
For 24-hour intervals, displays the date of the interval. For 15-minute
intervals, displays the date and ending time of the interval.
ES
Displays the number of seconds in the measuring interval during which
errors occurred.
SES
Displays the number of severe error seconds in the measuring interval.
UAS
Displays the Unavailable Seconds value of the measured interval. The value
can be between 0 and 900 seconds (15 minutes).
BBE
Displays the number of background block errors during the measured
interval.
Integrity
Indicates whether the values received at the time and date of the measured
interval are reliable. An x in the column indicates that the values are not
reliable due to a possible power surge or power failure that occurred at that
time.
5.6.7
Displaying MSE PMs and Configuring MSE PM Thresholds
To display modem MSE (Minimum Square Error) PMs per radio:
1 Select
Radio > PM & Statistics > MSE
. The MSE PM report page opens.
Figure 187: MSE PM Report Page
2 For the IP-20C and IP-20C-HP, in the
Interface
field, select the radio for which
you want to display PMs.
3 In the
Interval Type
field:
◦
To display reports in 15-minute intervals, select
15 minutes
.