Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2109
STM-1-OC-3-PBRS-
INSERTION
Alarm Equipment
PRBS insertion.
Warning
PRBS insertion on STM-
1/OC-3 card.
Remove PRBS insertion.
2110
STM-1-OC-3-SFP-
NOT-DETECTED
Alarm Equipment
SFP absent in STM-
1/OC-3 port.
Critical
1.
SFP is not properly
installed.
2.
SFP is faulty.
1.
Install SFP properly.
2.
Replace the card.
2111
STM-1-OC-3-SFP-
TX-FAILURE
Alarm Equipment
SFP Transmit Failure on
STM-1/OC-3 port.
Critical
1.
SFP is faulty.
1.
Replace SFP or insert SFP if
it is not inserted correctly.
2.
Replace the card.
2112
STM-1-OC-3-SFP-
TX-MUTED
Alarm Equipment
SFP is muted on STM-
1/OC-3 port.
Warning
SFP is muted by
configuration.
Remove muting.
2113
STM-1/OC-3-
CHANNEL-2-
REMOVED
Alarm Equipment
STM-1/OC-3 Channel
Removed alarm (due to
reduced radio capacity).
Warning
1.
Reduced capacity.
2.
Fading.
1.
Check link performance.
2.
Check radio alarms for
channel.
2114
STM-1/OC-3-
CHANNEL-3-
REMOVED
Alarm Equipment
STM-1/OC-3 Channel
Removed alarm (due to
reduced radio capacity).
Warning
1.
Reduced capacity.
2.
Fading.
1.
Check link performance.
2.
Check radio alarms for
channel.
2115
STM-1/OC-3-
CHANNEL-4-
REMOVED
Alarm Equipment
STM-1/OC-3 Channel
Removed alarm (due to
reduced radio capacity).
Warning
1.
Reduced capacity.
2.
Fading.
1.
Check link performance.
2.
Check radio alarms for
channel.
2116
STM-1/OC-3-
CHANNEL-5-
REMOVED
Alarm Equipment
STM-1/OC-3 Channel
Removed alarm (due to
reduced radio capacity).
Warning
1.
Reduced capacity.
2.
Fading.
1.
Check link performance.
2.
Check radio alarms for
channel.