User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 196 of 825
Ceragon Proprietary and Confidential
Note:
The
Operational Status
field indicates whether SNMP monitoring is
currently active (
Up
) or inactive (
Down
).
3 In the
SNMP Read Community
field, enter the community string for the SNMP
read community.
4 In the
SNMP Write Community
field, enter the community string for the
SNMP write community
5 In the
SNMP Trap Version
field, select
V1
,
V2
, or
V3
to specify the SNMP
version.
Note:
The
SNMP MIB Version
field displays the current SNMP MIB version
the unit is using.
6 In the
V1V2 Blocked
field, select
Yes
if you want to block SNMPv1 and
SNMPv2 access so that only SNMPv3 access will be enabled.
7 Click
Apply
.
If you are using SNMPv3, you must also configure SNMPv3 users. SNMPv3 security
parameters are configured per SNMPv3 user.
To add an SNMP user:
1 Select
Platform > Management SNMP > V3 Users
. The V3 Users page opens.
Figure 139: V3 Users Page
2 Click
Add
. The V3 Users - Add page opens.