User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 262 of 825
Ceragon Proprietary and Confidential
Figure 195: Frame Error PM Report Page
2 For the IP-20C and IP-20C-HP, in the
Port
field, select the port that holds the
radio for which you want to display PMs.
3 In the
Interval Type
field:
◦
To display reports in 15-minute intervals, select
15 minutes
.
◦
To display reports in daily intervals, select
24 hours
.
describes the capacity and throughput PMs.
Note:
To display the same parameters for a specific interval in a separate page,
select the interval in the PM table and click
View
.
Table 44: Frame Error Rate PMs
Parameter
Definition
Time interval
index
For 24-hour intervals, displays the date of the interval. For 15-minute intervals,
displays the date and ending time of the interval.
FER
Displays the frame error rate (%) during the measured time interval.
Integrity
Indicates whether the values received at the time and date of the measured
interval are reliable. An x in the column indicates that the values are not reliable
due to a possible power surge or power failure that occurred at that time.