11 Click
Next
. Page 3 of the Multiband Quick Configuration wizard opens.
Figure 63: Multiband Quick Configuration Wizard
–
Page 3
12 Configure the following radio parameters.
i
In the
TX Frequency (MHz)
field, set the transmission radio frequency in
MHz.
ii In the
RX Frequency (MHz)
field, set the received radio frequency in MHz.
iii In the
TX Level (dBm)
field, enter the desired TX signal level (TSL). The
range of values depends on the frequency and RFU type.
iv To mute the TX output of the radio, select
Mute
in the
TX mute
field. To
unmute the TX output of the radio, select
Unmute
. To configure a timed
mute, select
Mute with Timer
.
If you select
Mute with Timer
, an additional field appears:
Mute timeout
(minutes)
. This field defines a timer for the mute, in minutes (1-1440).
When the timer expires, the mute automatically ends. This provides a fail-
safe mechanism for maintenance operations that eliminates the possibility
of accidently leaving the radio muted after the maintenance has been
completed. By default, the timer is 10 minutes.
Note:
In contrast to an ordinary mute, a timed mute is not persistent. This
means that if the unit is reset, the radio is not muted when the unit
comes back online, even if the timer had not expired. Also, in unit and
radio protection configurations, a timed mute is not copied to the
mate unit or radio, and no mismatch alarm is raised if a timed mute is
configured on only one radio in the protection pair.