User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 795 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2031
pwe3-stm1oc3-s-
slm-alarm
Alarm Equipment
J0 Trace Identifier
Mismatch on TDM-LIC
STM1/OC3 port
Minor
1.
J0 misconfiguration.
2.
Line is not properly
connected.
3.
SFP is not properly
installed.
4.
External equipment
is faulty.
1.
Make sure expected and
received J0 match.
2.
Install SFP properly.
3.
Reconnect line.
4.
Check line cables.
5.
Check external equipment.
6.
Power cycle the TDM-LIC.
2032
pwe3-stm1oc3-s-
ssm-rx-changed
Event
Equipment
SSM pattern received
on TDM-LIC STM1/OC3
port changed
Warning
2033
pwe3-vc12vt15-s-
ais-alarm
Alarm Equipment
Alarm Indication Signal
(AIS) on TDM-LIC
VC12/VT1.5
Minor
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.
2034
pwe3-vc12vt15-s-
excessive-ber-
alarm
Alarm Equipment
Excessive BER on TDM-
LIC VC12/VT1.5
Minor
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.
2035
pwe3-vc12vt15-s-
loopback-alarm
Alarm Equipment
Loopback on TDM-LIC
VC12/VT1.5
Warning
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.