Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1794
interface-not-
functional-until-
reset
Alarm equipment
Interface is not
operational until chassis
reset
Warning
Changes were made to
platform due to user
configuration
Reset chassis
1800
t3-loc-alarm
Alarm Equipment
T3 sync interface Loss of
Carrier
Major
1.
Cable disconnected.
2.
Defective cable.
1.
Check connection of the
cable.
2.
Replace the cable.
2001
pwe3-pwc-s-card-
reset
Alarm Equipment
TDM-LIC has rebooted
and is not in service
now
Major
1.
Recent TDM-LIC card
reset;
2.
System malfunction.
1.
Wait for card to reboot.
2.
Reset the TDM-LIC card.
2002
pwe3-pwc-s-
config-mismatch
Alarm Equipment
TDM-LIC configuration
mismatch
Major
1.
Recent warm reset of
TDM-LIC;
2.
System malfunction.
Power cycle the TDM-LIC.
2003
pwe3-pwc-s-front-
panel-clock-los
Alarm Equipment
Loss of Signal (LOS) on
TDM-LIC's front panel
clock port
Major
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.
4.
Power cycle the TDM-LIC.
2004
pwe3-pwc-s-host-
pw-lic-comm-
disrupt
Alarm Equipment
Communication with
TDM-LIC is disrupted in
Host-Card direction
Minor
System malfunction
Reset the TDM-LIC.
2005
pwe3-pwc-s-hw-
failure
Alarm Equipment
TDM-LIC hardware
failure
Major
System malfunction
Reset the TDM-LIC.