3.7.2.2
Configuring Split Ethernet Interface Protection Mode (CLI)
To configure split Ethernet interface protection mode:
1 Use an optical splitter to route traffic to an optical Ethernet port on each IP-20
unit.
Configuring HSB Radio Protection
3.7.3
Configuring HSB Radio Protection
You must perform the initial configuration of a 1+1 or 2+2 HSB system using a
splitter cable for each unit to provide a management connection to each unit. For
instructions on preparing and connecting the splitter cables, refer to the
Installation Guide for IP-20C, IP-20C-HP, or IP-20S.
To configure HSB radio protection:
1 Before enabling protection, you must:
i
Verify that both units have the same hardware part number (see
) and the same software version (see
). If the units do not have the same software
version, upgrade each unit to the most recent software release (see
).
ii Assign an IP address to each unit. For instructions, see
iii Establish a management connection to one of the units. You can select
either unit; once you enable Protection Administration, the system will
determine which unit becomes the Active unit.
2 Select
Platform > Shelf Management > Unit Redundancy
. The Unit
Redundancy (HSB Protection) page opens.
Figure 102: Unit Redundancy Page