User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 167 of 825
Ceragon Proprietary and Confidential
To manually switchover to the Standby unit:
1 Select
Platform > Management > Unit Redundancy
. The Unit Redundancy
(HSB Protection) page opens (
).
2 Click
Manual Switch
.
3 Confirm the action in the confirmation window that appears.
3.7.9
Disabling Automatic Switchover to the Standby Unit
At any point, you can perform lockout, which disables automatic switchover to
the standby unit.
To disable automatic switchover to the Standby unit:
1 Select
Platform > Shelf Management > Unit Redundancy
. The Unit
Redundancy (HSB Protection) page opens (
).
2 Select
On
in the
Lockout
field.
3 Click
Apply
.
To re-enable automatic switchover, select
Off
in the
Lockout
field and then
click
Apply
.
3.7.10
Disabling Unit Protection
You can disable unit protection at any time. If you disable unit protection, keep in
mind that while the unit that was formerly the active unit maintains its IP address,
the unit that was formerly the standby unit is assigned the default IP address
(192.168.1.1)
To disable protection:
1 Select
Platform > Shelf Management > Unit Redundancy
. The Unit
Redundancy (HSB Protection) page opens (
).
2 Select
Disable
in the
Protection Admin
field.
3 Click
Apply
.