Source: Converter Max. Power
Defines the maximum tolerable input power at the RF In port of the converter.
Remote command:
[SENSe:]CONVerter:DEFinition:MPOWer
Local Port: Multiplicator
Defines the source multiplicator, i.e. the factor by which the incoming LO frequency is
multiplied by the converter.
Remote command:
[SENSe:]CONVerter:DEFinition:LMUL
Local Port: Nominal Power
Defines the preferred input power at the LO In port of the converter.
Remote command:
[SENSe:]CONVerter:DEFinition:LPOWer
Add/Copy
Use "Add" to create a converter type with default properties or use "Copy" to duplicate
the properties of the converter type whose tab is currently selected.
Remote command:
[SENSe:]CONVerter:DEFinition:DEFine
Delete
Deletes the converter type whose tab is currently selected.
Only user-defined converter types can be deleted.
Remote command:
[SENSe:]CONVerter:DEFinition:DELete
5.19.6.3
Default Cable and Splitter Losses dialog
After the converter ports have been set up in the
Converter Configuration dialog
can configure the converter port-specific cable and splitter losses and slope factors.
Access:
System – [Setup] > "Frequency Converter" > "Default Cable and Splitter Los-
ses..."
Setup softtool