The velocity factor is a measure for the velocity of an electromagnetic wave in a dielec-
tric with permittivity ε
r
, relative to its velocity in a vacuum (velocity factor < 1).
Permittivity and velocity factor are coupled parameters, i.e. setting one of them deter-
mines the other. A higher permittivity implies a smaller mechanical length, but leaves
delay and electrical length unchanged (see
Max. DUT Measure Delay / Max. El.
).
Remote command:
[SENSe<Ch>:]HARMonic:PERMittivity:DATA
[SENSe<Ch>:]HARMonic:VELocity:DATA
Rise Time Definition
Selects between rise time definitions 10%-90% (default) and 20%-80%.
Remote command:
[SENSe<Ch>:]HARMonic:RTIMe:THReshold
Rise Time
The minimum rise time (according to the selected
wishes to measure on the DUT.
This in turn determines the stop frequency of the frequency sweep: the smaller the
"Rise Time", the larger the stop frequency – limited by the analyzer's maximum fre-
quency.
Remote command:
[SENSe<Ch>:]HARMonic:RTIMe:DATA
TDR Stimulus - Advanced Settings dialog
The "TDR Stimulus - Advanced Settings " compiles advanced settings of the time
domain transformation that is available with the standard time domain option
R&S
ZNA-K2.