GUI reference
R&S
®
ZNA
771
User Manual 1178.6462.02 ─ 20
Add Trace + Diagram
Creates a diagram and a trace which is displayed in the new diagram. The trace is cre-
ated with the channel settings of the previous active trace but with default trace set-
tings. The new diagram area is numbered <n>, where <n> is the largest of all existing
diagram area numbers plus one.
Tip:
Dragging the "Trc+" toolbar icon to a new diagram area is similar to "Add Trace +
Diagram".
Remote command:
ON
Delete Diagram
Deletes the current diagram area including all traces displayed in the diagram area.
The remaining diagrams are renumbered; each recall set always contains diagrams
with contiguous numbers. "Delete Diag Area" is disabled if the recall set contains only
one diagram area: In manual control, each recall set must contain at least one diagram
area with one channel and one trace.
Tip:
To restore a diagram area that was unintentionally deleted, use the undo function-
ality.
Remote command:
OFF
Maximize Diagram
Maximizes the active diagram or restores the previous diagram arrangement.
For other split types, use the functions in the
Remote command:
DISPlay[:WINDow<Wnd>]:MAXimize
Title
Defines a title for the
The visibility of the title area can be toggled using
.
Remote command:
DISPlay[:WINDow<Wnd>]:TITLe:DATA
Via remote control, it is also possible to define a diagram
name
, and to retrieve the
lists of diagrams together with their names:
DISPlay[:WINDow<Wnd>]:NAME
DISPlay[:WINDow<Wnd>]:CATalog?
Display softtool