GUI reference
R&S
®
ZNA
686
User Manual 1178.6462.02 ─ 20
Total Port Ordering
Tells the SFD tool about the port ordering of the test fixture
●
"Ports 1&3 on Left" (default): odd ports are on the left and even ports are on the
right
●
"Ports 1&2 on Left" ports 1 to N are on the left and ports N+1 to 2·N are on the
right
Remote command:
CALCulate:FMODel:SFD<Ph_pt>:TOTaldiffcfg
Adjust Impedance Mismatch
If checked, the SFD tool performs automatic impedance adjustments.
Remote command:
CALCulate:FMODel:SFD<Ph_pt>:AUTO
5.14.5.8
EZD Advanced Settings
Allows you to specify advanced parameters for the EZD tool.
Port Order
Tells the EZD tool about the port ordering of the test coupon
●
"Odd on left" (default): odd ports are on the left and even ports are on the right
●
"1 to N on left" ports 1 to N are on the left and ports N+1 to 2·N are on the right
Remote command:
CALCulate:FMODel:EZD<Ph_pt>:PORT:ORDer
Generate Side 1/Generate Side2
If checked (default), the tool generates the deembedding file for side 1 / side 2.
Offset Embed softtool