Command reference
R&S
®
ZNA
1532
User Manual 1178.6462.02 ─ 20
Query parameters:
<TrigSource>
ANY
For Keysight PNA Compatibility, ANY (and only ANY) is accep-
ted as parameter.
Usage:
Query only
TRIGger:WAIT:READy?
[<Timeout>]
Returns 1 when the R&S
ZNA is "Ready for Trigger", or 0 after the specified <Time-
out>.
Query parameters:
<Timeout>
Timeout value (optional, default 1 ms)
Default unit: s
Usage:
Query only
7.3.20
New commands for R&S
ZNA
Mixer phase and delay measurements
............................................................... 1532
........................................................................................1540
...........................................................................1542
............................................................................................... 1543
7.3.20.1
Mixer phase and delay measurements
Mixer phase calibration (R&S
ZNA-K5)
[SENSe<Ch>:]CORRection:POWer:MIXer:IF:ACQuire
.....................................................1532
[SENSe<Ch>:]FREQuency:CONVersion:MIXer:PRFimage
...............................................1533
SOURce<Ch>:POWer:CORRection:MIXer:IF[:ACQuire]
...................................................1533
SOURce<Ch>:POWer:CORRection:MIXer:LO<Stg>[:ACQuire]
........................................ 1534
SOURce<Ch>:POWer:CORRection:MIXer:RF[:ACQuire]
................................................. 1534
[SENSe<Ch>:]CORRection:POWer:MIXer:IF:ACQuire
Starts the IF receiver calibration (2nd power calibration step for scalar mixer measure-
ments), stores and applies the calibration data.
Note:
The receiver calibration relies on the IF source power calibration acquired in
step no. 1.
[SENSe<Ch>:]CORRection:POWer<PhyPt>:MIXer:IF:ACQuire
is
enabled only after step 1 has been carried out
(
SOURce<Ch>:POWer<PhyPt>:CORRection:MIXer:RF[:ACQuire]
).
Suffix:
<Ch>
.
Calibrated channel number
SCPI command reference