Command reference
R&S
®
ZNA
908
User Manual 1178.6462.02 ─ 20
CALCulate<Chn>:EYE:JITTer:PERiodic:FREQuency
<PeriodicFrequency>
Defines the frequency of the periodic jitter in the generator simulation of the related eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Periodic jitter insertion can be enabled using
CALCulate<Chn>:EYE:JITTer:TYPE:
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<PeriodicFrequency> *RST:
10 MHz
Default unit: Hz
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:JITTer:PERiodic:MAGNitude
<PeriodicMagnitude>
Defines the magnitude of the periodic jitter in the generator simulation of the relaed eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Periodic jitter insertion can be enabled using
CALCulate<Chn>:EYE:JITTer:TYPE:
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<PeriodicMagnitude> *RST:
1 ns
Default unit: s
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:JITTer:PERiodic:PHASe
<PeriodicPhase>
Defines the phase of the periodic jitter in the generator simulation of the related eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Periodic jitter insertion can be enabled using
CALCulate<Chn>:EYE:JITTer:TYPE:
.
SCPI command reference