Command reference
R&S
®
ZNA
1118
User Manual 1178.6462.02 ─ 20
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:SHUNt?
............................................................... 1128
CONTrol:RFFE<Bus>:TEST:DATA:VOLTage?
................................................................. 1129
CONTrol:RFFE<Bus>:TEST:CLOCk:VOLTage?
...............................................................1129
CONTrol:RFFE<Bus>:TEST:VIO:VOLTage?
....................................................................1129
CONTrol:RFFE<Bus>:TEST:DATA:CURRent?
.................................................................1129
CONTrol:RFFE<Bus>:TEST:CLOCk:CURRent?
.............................................................. 1129
CONTrol:RFFE<Bus>:TEST:VIO:CURRent?
................................................................... 1129
CONTrol<Ch>:SEGMent<Nr>:SEQuence:COUNt?
.......................................................... 1129
CONTrol<Ch>:SEGMent<Nr>:SEQuence:CLEar:ALL
...................................................... 1130
............................................................................. 1130
CONTrol<Ch>:SEGMent<Nr>:GPIO<Port>:VOLTage
.......................................................1130
CONTrol<Ch>:SEGMent<Nr>:RFFE<Bus>:COMMand:DATA
........................................... 1131
CONTrol<Ch>:SEQuence:CLEar:ALL
.............................................................................1131
................................................................................ 1131
CONTrol<Ch>:SEQuence<Nr>:DELay
............................................................................1132
CONTrol<Ch>:SEQuence<Nr>:GPIO<Port>:VOLTage
..................................................... 1132
CONTrol<Ch>:SEQuence<Nr>:RFFE<Bus>:COMMand:DATA
..........................................1133
............................................................................................... 1133
........................................................................................ 1133
.........................................................................................1134
................................................................................................1134
............................................................................................ 1134
CONTrol:AUXiliary:C[:DATA]
<DecValue>
Sets or queries a channel-dependent eight-bit decimal value to control eight independ-
ent output signals at the User Port connector (lines 8, 9, 10, 11 and lines 16, 17, 18,
19). The output signals are 3.3 V TTL signals which can be used to differentiate
between up to 255 independent analyzer states.
CONTrol:AUXiliary:C[:DATA]
itself does not change the analyzer state.
Channel bit definition and activation
The channel bits have the following properties:
●
After a
*RST
of the analyzer all channel bits (including the value for the active,
sweeping channel no. 1) are set to zero; no signal is applied to pins 8 to 11 and 16
to 19 of the User Port connector.
●
The value defined with
CONTrol:AUXiliary:C[:DATA]
is assigned to the
active
).
●
The signals at the User Port connector reflect the channel bits of the
measuring
channel, i.e. the channel for which the analyzer performs a sweep. This channel is
not necessarily identical with the active channel.
●
The signals are switched on as soon as a measurement (sweep) in a channel with
non-zero channel bits is started. They are changed whenever a channel with differ-
ent channel bits becomes the measuring channel.