background image

UC-260 Wireless Acoustic Indicator 

1 / 2 

MFI51405 

 

UC-260 Wireless Acoustic Indicator

 

 

The UC-260 can be used as a wireless indoor siren, a melody doorbell 

or as a chime. It can also function as a small house alarm. The UC-260 
is  compatible  with  Jablotron  wireless  control  panels  (JA-60,  
JA-63  and  JA-65),  JA-60  wireless  detectors  and  RC-11,  RC-40,  RC-22 
and  RC-28  remote  controls.  Several  triggering  devices  can  be  used 
simultaneously  and  different  melodies  can  be  assigned  to  each  device. 
Two  different  sound  levels  can  be  selected.  The  UC-260  provides 
entrance and exit delay chirps too, when used with a control panel.  

 

Specification 

 

Power supply 

110-230 V, 50-60 Hz 

Power consumption 

1.5 W 

Electrical protection- Class (EN60950) 

II   

Acoustics 

8 melodies and/or 100 dB/m alarm siren 

Input wireless devices  

max. 8 remote controls or detectors 

 

1 control panel JA-60, JA-63 or JA-65 

Working frequency 

433,92 MHz 

Environmental conditions 

interior 

–10 to +40°C 

Degree of protection  

IP40 according to EN 60529 

Can be operated according to ERC REC 70-03 

Hereby,  JABLOTRON  ALARMS,  declares  that  this  UC-260

 

is  in 

compliance  with  the  essential  requirements  and  other  relevant 
provisions of Directive 1999/5/EC and 2011/65/EU. 

Original  of  the  conformity  assessment  can  be  found  at  the  web  page 

www.jablotron.com

section Technical support.

 

 

 

Installation 

 

UC-260 is powered directly from a power outlet. The device should not 

be  installed  close  to  any  metal  structures  or  other  objects  obstructing 
radio signal transmission.  

 

Enrolling of wireless components

 

 

1. Press and hold the button on the top of the UC-260. 

2. Plug in the UC-260 to an outlet 

and hold the button until you hear 

2 beeps.  

3. Release the button 

– The button will begin to flash, indicating it is in 

the programming mode. 

4. Enrolling of components: 

 

Doorbell  button 

(RC-11,  RC-40,  RC-22,  RC-28,  RC-60)  can  be 

enrolled by pressing a button on the controller or by triggering an 
input.  Multiple  pressing  of the controller

’s button will allow you to 

scroll to a desired melody. 

 

Detector  -  chime

 

mode 

(JA-60  detectors)  can  be  enrolled  by 

inserting  batteries  into  a  detector.  You  can  scroll  to  a  desired 
melody by pressing the tamper switch. 

 

Control  panel 

– siren mode

 (JA-60, JA-63 or 65) 

– while in the 

service mode of the control panel, enter code 299. 

 

 

5. 

Up  to  8  doorbell  buttons  or  detectors  plus  1  control  panel  can  be 
used with one UC-260. 

6. Exit  the  programming  mode

  by  pressing  the  UC-260

’s  button 

briefly. 

 

  

If  you  enter  the  programming  mode  the  way  above,  all  enrolled 
components will be erased from the memory. 

 

 

Adding components  

 

If you want to add additional doorbell buttons or detectors or if you 

want to select another melody for an existing component, than:  

1. Unplug the UC-260 from the outlet 

and wait for 5 seconds. 

2. Plug it in again.

 

3. The button will light  

– press it and hold it down. 

 

4. After  hearing  a  short  beep,  release  the  button.   

The  flashing 

button indicates it is in the programming mode. 

5. Enrolling new components 

(or selecting another melody): 

 

RC  remote  control 

(RC-11,  RC-40,  RC-22,  RC-28,  RC-60)  can 

be enrolled by pressing a button on the controller or activating its 
input.  Multiple  pressing  of the controller

’s button will allow you to 

scroll to a desired melody. 

 

Detector 

(JA-60  detectors) can  be  enrolled  by  inserting  batteries 

into a detector. You can scroll to a desired melody by pressing the 
tamper switch. 

 

Control panel 

(JA-60, JA-63 or 65) 

– while in the service mode of 

the control panel, enter code 299. 

 

6. 

Up to 8 buttons or detectors plus 1 control panel can be used with UC-
260. 

 

7. Exit the programming mode

 by pressing the UC-260 button briefly. 

 

 

Deleting components 

 

Press and hold a red button on the UC-260 and plug the UC-260 into 

the mains outlet. Hold the button until two beeps can be heard indicating 
that all components have been erased.  

 

Loudness selection 

 

  The UC-260 must be in its operating mode (plugged in). 

  Press and hold the button down. 

  After 2 sec you will hear a melody with the new loudness selected 

 

Release the button. 

 

This  way  you  can  toggle  between  a  standard  and  a  louder  one. 

This setting doesn’t affect the alarm siren sound. 

 

Note:

 even though this product does not contain any harmful materials 

we suggest you to return the product to the dealer or directly to the 
producer after usage.

Reviews: