UC-260 Wireless Acoustic Indicator
2 / 2
MFI51405
Doorbell mode
After pressing a doorbell button, the UC-260 will play a selected
melody. Different melodies can be chosen for each button, if desired.
If you want to change a melody, enter the programming mode (See
Adding components) and press the button until a desired melody is
selected.
Detector chime mode
If an enrolled detector is triggered, the UC-260 will play a chosen
melody. The melody can be changed if desired (See Adding
components).
A detector enrolled to the UC-260 can be enrolled to a JA-60 or
JA-65 security control panel too. For example, this way a wireless door
detector can activate a chime with the UC-260 and at the same time it
can trigger an alarm system.
Notes:
1/ JA-60P motion detector uses a special sleeping mode feature (can
be set to 5 min. or 1 min.). Therefore it cannot detect more frequent
movements in a covered area.
2/ Fire detectors (e.g. JA-60S, JA-60G) cannot be used for the chime
mode.
Wireless siren mode
If a control panel is enrolled to a UC-260, the UC-260
’s light indicator
copies the status of the PgY control panel output. If an alarm is
triggered, the siren of the UC-260 sounds. Also an exit and entrance
delay can be indicated. The exit and entrance delay indication can be
set in two ways, which you can change by sending the learning code
from the control panel:
1. When a control panel is enrolled for the first time and one beep is heard,
than no chirps will be performed by UC-260.
2. When two beeps are heard, then chirps will be performed on the
UC-260.
You can toggle between these two settings each time you enroll the
control panel to the UC-260 (entering 299 code while in the service
mode).
Indicator can be also used as a minialarm. For more details ask your
supplier or visit Jablotron’s web page www.jablotron.com.