MMEMory:LOAD:VNETworks<Ch>:GLOop:DEEMbedding<group>
<TouchstoneFile>
MMEMory:LOAD:VNETworks<Ch>:GLOop:EMBedding<group>
<TouchstoneFile>
Loads data from a specified one-port (
*.s1p
) Touchstone file defining a ground loop
circuit model for de-/embedding.
Suffix:
<Ch>
.
Channel number
<group>
Port group (DUT) number.
If multiple port groups are configured (see
ON
, then each port group can
have its own ground loop de-/embedding model.
Parameters:
<TouchstoneFile>
String parameter to specify the name and directory of the loaded
Touchstone file.
If no path is specified the analyzer searches the current direc-
tory, which can be set and queried using
Example:
CALC:TRAN:VNET:SEND:GLO:TND FIMP
Select the 1-Port Data (s1p) circuit model.
MMEM:LOAD:VNET:GLO:EMB 'C:\Users\Public\
Documents\Rohde-Schwarz\ZNA\Embedding\Test.s1p'
Load a Touchstone file.
Manual operation:
See
MMEMory:LOAD:VNETworks<Ch>:PPAir:DEEMbedding<ListId>
<TouchstoneFile>[, <Port>[, <Interchange>]]
MMEMory:LOAD:VNETworks<Ch>:PPAir:EMBedding<ListId>
<TouchstoneFile>[,
<Port>[, <Interchange>]]
Loads the S-parameter data that (partly) specify the deembedding network of port
group
<ListId>
from local Touchstone files.
Use
CALCulate<Ch>:TRANsform:VNETworks:PPAir:DEEMbedding<ListId>:
or
CALCulate<Ch>:TRANsform:VNETworks:PPAir:
EMBedding<ListId>:TNDefinition
to select the desired
before
loading the data files.
●
For any n-port set, the
FIMPort
model requires a single
*.s<2n>p
file and hence
a single set command.
●
For 2-port sets (port pairs), the circuit models
STSL | STSC | SLST | SCST
require 2
*.s2p
files, that have to be assigned to the appropriate port using two
set commands.