3
66
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units
Controlled deceleration on
power loss
Four option codes:
Trips
Decelerates to a stop
Decelerates to a stop with DC
bus voltage controlled
Decelerates to a stop with DC
bus voltage controlled, then
restart
00
DC bus voltage trigger
level of ctrl. decel.
Setting of DC bus voltage to start
controlled decel. operation. Range
is 0.0 to 1000.0
220.0/
440.0
V
Over-voltage threshold of
ctrl. decel.
Setting the OV-LAD stop level of
controlled decel. operation. Range
is 0.0 to 1000.0
360.0/
720.0
V
Deceleration time of ctrl.
decel.
Range is 0.01 to 3600.0
1.0
sec
Initial freq. drop of ctrl.
decel.
Setting of initial freq. drop.
Range is 0.0 to 10.0 Hz
0.0
Hz