
Ver.3
−
−
−
−
134
““““b
b
b
b”””” Function
Function
Function
Function
A
A
A
A
B
B
B
B
D
D
D
Defaults
efaults
efaults
efaults
Func.
Func.
Func.
Func.
Code
Code
Code
Code
N
N
N
Name
ame
ame
ame
D
D
D
Description
escription
escription
escription
Initial data
Initial data
Initial data
Initial data
Units
Units
Units
Units
b
b
b
b1
1
1
16
6
6
63
3
3
3
Frequency set in
monitoring
Two option codes:
00
00
00
00
…
Freq. set disabled
0
0
0
01
1
1
1
…
Freq. set enabled
00
-
b
b
b
b1
1
1
16
6
6
64
4
4
4
Automatic return
to the initial
display
10 min. after the last key operation, display returns to the initial
parameter set by b
b
b
b0
0
0
03
3
3
38
8
8
8. Two option codes:
00
00
00
00
…
Disable
0
0
0
01
1
1
1
…
Enable
00
-
b
b
b
b1
1
1
16
6
6
65
5
5
5
Ex. operator com.
loss action
Five option codes:
00
00
00
00
…
Trip
0
0
0
01
1
1
1
…
Trip after deceleration to a stop
0
0
0
02
2
2
2
…
Ignore
0
0
0
03
3
3
3
…
Coasting (FRS)
0
0
0
04
4
4
4
…
Decelerates to a stop
02
-
b
b
b
b1
1
1
166
66
66
66
Data Read/Write
select
00
00
00
00
…
Read/Write OK
0
0
0
01
1
1
1
…
Protected
00
-
b
b
b
b1
1
1
17
7
7
71
1
1
1
Inverter mode
selection
Three option codes:
00
00
00
00
…
No function
0
0
0
01
1
1
1
…
Std. IM (Induction Motor)
0
0
0
02
2
2
2
…
Reserved
0
0
0
03
3
3
3
…
PM (Permanent Magnet Motor)
00
-
b
b
b
b1
1
1
18
8
8
80
0
0
0
Initialization
trigger
This is to perform initialization by parameter input with b
b
b
b0
0
0
08
8
8
84
4
4
4,
b
b
b
b0
0
0
08
8
8
85
5
5
5 and b
b
b
b0
0
0
09
9
9
94
4
4
4. Two option codes:
00
00
00
00
…
Initialization disable
0
0
0
01
1
1
1
…
Perform initialization
00
-
b
b
b
b1
1
1
19
9
9
90
0
0
0
Password
Settings A
0000(Invalid Password)
0001-FFFF(Password)
0000
-
b
b
b
b1
1
1
19
9
9
91
1
1
1
Password
authentication A
0000-FFFF
0000
-
b
b
b
b1
1
1
19
9
9
92
2
2
2
Password
Settings B
0000(Invalid Password)
0001-FFFF(Password)
0000
-
b
b
b
b1
1
1
19
9
9
93
3
3
3
Password
authentication B
0000-FFFF
0000
-
b
b
b
b9
9
9
91
1
1
10
0
0
0
*2
Electronic
thermal
subtraction
function selection
00
00
00
00…OFF
0
0
0
01
1
1
1…Linear subtraction: pre-fixed ratio
0
0
0
02
2
2
2…Linear subtraction: ratio set in b911
0
0
0
03
3
3
3…Subtraction with first-order lag filter:
ratio set in b912
03
−
b
b
b
b9
9
9
911
11
11
11
*2
Thermal
subtraction time
0.10 to 100000.00[s] (upper four digits are shown)
600.0
s
b
b
b
b9
9
9
91
1
1
12
2
2
2
*2
Thermal
subtraction time
constant
0.10 to 100000.00[s] (upper four digits are shown)
120.00
s
b
b
b
b9
9
9
91
1
1
13
3
3
3
*2
Thermal
accumulation
gain
1.0 to 200.0 [%]
100.0
%
*2
: Available from version 3.0
*3
: Power cycle is required to reflect a change.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......