“C” Group: Intelligent Terminal Functions
The seven input terminals [1], [2], [3], [4], [5], [6], and [7] can be configured for any of 72
different functions. The next two tables show how to configure the seven terminals. The
inputs are logical, in that they are either OFF or ON. We define these states as OFF=0,
and ON=1.
The inverter comes with default options for the seven terminals. These settings are
initially unique, each one having its own setting. Note that European and US versions
have different default settings. You can use any option on any terminal, and even use
the same option twice to create a logical OR (though usually not required).
NOTE: Terminals [3] and [4] have the ability to be logical inputs, and to be safety inputs
in case of safe stop function is selected.
NOTE: Terminal [5] has the ability to be a logical input, and to be an analog input for a
thermistor device when PTC function (option code 19) is assigned to that terminal.
Input Terminal Configuration
Functions and Options – The
function codes
in the following table let you assign one of
seventy-two options to any of the seven logic inputs for the XJ200 inverters. The
functions
through
configure the terminals [1] through [7] respectively. The
“value” of these particular parameters is not a scalar value, but it is a discrete number
that selects one option from many available
options
.
For example, if you set function
=
, you have assigned option
(Forward Run) to
terminal [1]. The option codes and the specifics of how each one works are in Chap. 4.
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units
Input [1] function
Select input terminal [1] function,
68 options (see next section)
Select input terminal [2] function,
68 options (see next section)
Select input terminal [3] function,
68 options (see next section)
Select input terminal [4] function,
68 options (see next section)
Select input terminal [5] function,
68 options (see next section)
Select input terminal [6] function,
68 options (see next section)
Select input terminal [7] function,
68 options (see next section)
00
[FW]
Input [2] function
01
[RV]
Input [3] function
[GS1 assignable]
12
[EXT]
Input [4] function
[GS2 assignable]
18
[RS]
Input [5] function
[PTC assignable]
02
[CF1]
Input [6] function
03
[CF2]
Input [7] function
06
[JG]
The input logic conversion is programmable for each of the seven inputs default to
normally open (active high), but you can select normally closed (active low) in order to
invert the sense of the logic.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......