Ver.3
−
−
−
−
149
““““H
H
H
H”””” Function
Function
Function
Function
A
A
A
A
B
B
B
B
D
D
D
Defa
efa
efa
efaults
ults
ults
ults
Func.
Func.
Func.
Func.
Code
Code
Code
Code
N
N
N
Name
ame
ame
ame
D
D
D
Description
escription
escription
escription
Initial data
Initial data
Initial data
Initial data
Units
Units
Units
Units
H
H
H
H232
232
232
232
Motor constant L,
2
nd
motor (Auto tuned data)
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
mH
H
H
H
H0
0
0
033
33
33
33
Motor constant I0
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
0.01 to 655.35A
A
H
H
H
H233
233
233
233
Motor constant I0,
2
nd
motor (Auto tuned data)
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
A
H
H
H
H0
0
0
034
34
34
34
Motor constant J
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
0.001 to 9999 kgm
2
kgm
2
H
H
H
H234
234
234
234
Motor constant J,
2
nd
motor (Auto tuned data)
(Auto tuned data)
(Auto tuned data)
(Auto tuned data)
kgm
2
H
H
H
H0
0
0
05
5
5
50
0
0
0
Slip compensation P
gain for V/f control with
FB
0.00 to 10.00
0.20
Times
H
H
H
H0
0
0
05
5
5
51
1
1
1
Slip compensation I gain
for V/f control with FB
0. to 1000
2
s
PM Motor Constants Functions
““““H
H
H
H”””” Function
Function
Function
Function
A
A
A
A
B
B
B
B
D
D
D
Defaults
efaults
efaults
efaults
Func.
Func.
Func.
Func.
Code
Code
Code
Code
N
N
N
Name
ame
ame
ame
D
D
D
Description
escription
escription
escription
Initial data
Initial data
Initial data
Initial data Units
Units
Units
Units
H
H
H
H1
1
1
10
0
0
02
2
2
2
PM motor code setting
00
00
00
00
…
Hitachi standard
(Use H106-H110 for motor
constants)
0
0
0
01
1
1
1
…
Auto-Tuning
(Use
H109-H110,
H111-H113
for
motor
constants)
00
-
H
H
H
H1
1
1
10
0
0
03
3
3
3
PM motor capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/
3.0/3.7/4.0/5.5/7.5/11.0/15.0/18.5
Specified by
the capacity
of each
inverter
mode
kW
H
H
H
H1
1
1
10
0
0
04
4
4
4
PM motor pole setting
2/4/6/8/10/12/14/16/18/20/22/24/26/
28/30/32/34/36/38/40/42/44/46/48
Poles
H
H
H
H1
1
1
10
0
0
05
5
5
5
PM Rated Current
(0.00 to 1.00)
×
Rated current of
the inverter [A]
A
H
H
H
H1
1
1
10
0
0
06
6
6
6
PM const R(Resistance)
0.001 to 65.535 [Ω]
Ohm
H
H
H
H1
1
1
10
0
0
07
7
7
7
PM const Ld
(d-axis inductance)
0.01 to 655.35 [mH]
mH
H
H
H
H1
1
1
10
0
0
08
8
8
8
PM const Lq
(q-axis inductance)
0.01 to 655.35 [mH]
mH
H
H
H
H1
1
1
10
0
0
09
9
9
9
PM const Ke
(Induction voltage
constant)
0.0001 to 6.5535 [V/(rad/s)]
V/
(rad/s)
H
H
H
H11
11
11
110
0
0
0
PM const J
(Moment of inertia)
0.001 to 9999.000 [kgm
2
]
kgm
2
H
H
H
H111
111
111
111
PM const R
(Resistance, Auto)
0.001 to 65.535 [Ω]
Specified by
the capacity
of each
inverter
mode
Ohm
H
H
H
H11
11
11
112
2
2
2
PM const Ld
(d-axis inductance, Auto)
0.01 to 655.35 [mH]
mH
H
H
H
H11
11
11
113
3
3
3
PM const Lq(q-axis
inductance, Auto)
0.01 to 655.35 [mH]
mH
H
H
H
H11
11
11
116
6
6
6
PM Speed Response
1 to 1000 [%]
100
%
H
H
H
H11
11
11
117
7
7
7
PM Starting Current
20.00 to 100.00 [%]
70.00
%
H
H
H
H11
11
11
118
8
8
8
PM Starting Time
0.01 to 60.00 [s]
1.00
s
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......