LAD cancel by setting ACC/DEC
•
The lower limit of the acceleration/deceleration time's set range, such as F002/F003,is 0.00.
Object parameter:
F002, F202, F003, F203, A092, A292, A093, A293
•
When the applied acceleration/deceleration time is 0.00[s], the inverter operate similar to LAC ON.
•
The inverter sets the instruction frequency into the output frequency whenever the driving instruction FW/RV
is ON and LAC is ON. And, the inverter sets 0Hz into the output frequency when the driving instruction
FW/RV is OFF.
Analog input O/OI monitor (always active)
•
About “Analog input O”, monitor display (d130) newly added. Its data range is 0-1023 and always active.
About “Analog input OI”, monitor display (d131) newly added. Its data range is 0-1023 and always active.
Pulse train input monitor (always active)
•
The monitor of the pulse train input to the terminal EA is always valid and is independent of any parameter
setting. That is displayed in the menu "d133" newly installed. That is the value after the Full Scale (P055)
conversion and the filter processing with the time constant (P056), and before bias(P057) processing. The unit of
the data is [0.01% (Full Scale (P055) standard)].The data can be read from Modbus and EzSQ.
×
A004
Frequency
command
%
Hz
Bias / limit / cut
0%
P059
P058
P057
100%
÷
Pulse input
P055 (1.0~32.0 kHz)
1
1+sT
P056 (0.01~2.00s)
kHz
%
d133(0.00 ~ 100.00 [%])
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......