4
63
Torque Limited Signal
The inverter outputs the torque limited signal when it is in torque limit operation.
To enable this function, assign “
(TRQ)” to an intelligent output terminal.
Refer to section 3 for detailed explanation.
Option
Code
Terminal
Symbol
Function Name
State
Description
TRQ
Torque limited
signal
ON
Inverter is in torque limiting mode
OFF
Inverter is not in torque limiting mode
Valid for inputs:
11, 12, AL0
– AL2
Example for terminal [11] (default output
configuration shown
– see
page 3-89
):
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration
– see
page 4-51 and 3-91
):
See I/O specs on
page 4-6
Required settings
=
,
~
Notes:
The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter’s output transistor.
RY
Inverter output
terminal circuit
CM2
11
TRQ
AL1
Power
supply
Load
AL0
AL2
Inverter logic
circuit board
TRQ
Summary of Contents for WJ200-001L