Special monitor display (-S--, -F**) cancellation
・
The parameter of b147 can be used to select whether special monitor display is canceled temporarily by
pressing down a key on the keypad during special monitor display (-S--, -F**) is displayed. Please refer to
table Ver.3.1-5 for details of special monitor display.
・
In the case of b147=00 (Cancellation of special display is invalid) setting, key operation is not accepted at all,
and special monitor display (-S--, -F**) is kept on being displayed.
・
In the case of b147=01 (Cancellation of special display is valid) setting, special monitor display is canceled
temporarily by pressing a key on the keypad and then normal display (parameter display) is displayed.
・
After having canceled special monitor display, it returns to an original special monitor display content if no
key operation has been done for the time specified by b148 (Special monitor display re-display time). If
content of special monitor display is changed due to transition of signal status, it displays corresponding
special monitor display content immediately regardless of the cancellation time. (e.g.: change into “-F**”
state from “-S--” state)
・
b148 can adjust the time to re-display special monitor display after it has been cancelled. Special display is
displayed again after passing time specified by b148 from the last key operation.
Table Ver.3.1-6
Func.
Func.
Func.
Func.
Code
Code
Code
Code
Name
Name
Name
Name
Description
Description
Description
Description
A
A
A
A B
B
B
B Initial data
Initial data
Initial data
Initial data
Modbus
Modbus
Modbus
Modbus register
register
register
register
number
number
number
number
Resolution
Resolution
Resolution
Resolution
b147
b147
b147
b147
Special monitor display
cancellation
00
00
00
00
…
Cancellation of special display
is invalid
0
0
0
01
1
1
1
…
Cancellation of special display
is valid
01
13d0h
-
b148
b148
b148
b148
Special monitor display
re-display time
Time to return to special display,
range is 1 to 30 sec.
30
13d1h
1 [sec]
Increase of upper limit up of BRD Activation Level
・
The upper limit of b096 “BRD Activation Level” of 200V and 400V class are increased by 10V and 20V
respectively.
Table Ver.3.1-7
Func.
Func.
Func.
Func.
Code
Code
Code
Code
Name
Name
Name
Name
Description
Description
Description
Description
A
A
A
A B
B
B
B Initial data
Initial data
Initial data
Initial data
Modbus
Modbus
Modbus
Modbus register
register
register
register
number
number
number
number
Resolution
Resolution
Resolution
Resolution
b096
b096
b096
b096
BRD activation level
When internal DC voltage exceeds
the specified level, BRD circuit is
activated. When internal DC
voltage falls below the level, BRD
circuit is inactivated.
(Ver. 3.0 or before)Range is:
330 to 380 V (200V class)
660 to 760 V (400V class)
(Ver. 3.1 or after)Range is:
330 to 390 V (200V class)
660 to 780 V (400V class)
360/
720
1363h
1 [V]
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......