Ver.3
−
−
−
−
7
Output frequency range from 0.01Hz to 400Hz
•
Start frequency adjustment – When the inverter starts to run, the output frequency does not ramp from 0Hz.
Instead, it steps directly to the “Start frequency” (b082), and the ramp proceeds upward from there. When you
set the “Start frequency” to 0.01Hz, the output frequency starts from 0.01Hz.
The Following are the related parameters for this function.
Func.
Func.
Func.
Func.
Code
Code
Code
Code
Name
Name
Name
Name
Description
Description
Description
Description
b
b
b
b0
0
0
08
8
8
82
2
2
2
Start frequency
0.01
~
9.99[Hz]
〈
Caution
〉
If you set the “Set frequency” (F001) to extremely low value, the motor may stall or be unstable rotating.
Especially in the simple positioning mode, if you set the “Creep speed” (P015) to low value, the simple
positioning may not work properly because of motor stalled.
Support of multiple pole 3 Phase Induction motors
(Up to 48 pole motor)
•
Following are the related parameters for this function.
Func.
Func.
Func.
Func.
Code
Code
Code
Code
Name
Name
Name
Name
Description
Description
Description
Description
H
H
H
H00
00
00
004
4
4
4
Motor poles setting
2(0)/4(1)/6(2)/8(3)/10(4)/12(5)/14(6)/16(7)/18(8)/
20(9)/22(10)/24(11)/26(12)/28(13)/30(14)/32(15)/
34(16)/36(17)/38(18)/40(19)/42(20)/44(21)/46(22)/
48(23)[pole(data)]
H
H
H
H2
2
2
20
0
0
04
4
4
4
Motor poles setting,
2nd motor
〈
Caution
〉
In the case of "Motor capacity" (H003/H203) and "motor poles setting" (H004/AH204) are configured to
correspond with the motor, the values of "motor constant data" (H020/H220 to H024/H224) are
automatically overridden by Hitachi standard motor's value.
With Hitachi inverter, if 8 poles or more poles are set up, 8 poles, which is Hitachi Standard mortar value,
are automatically applied. If necessary, manually configure motor constants.
Please note working of motors with 8 poles or more are not guaranteed. Some mortar may work unstable
in such cases.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......