3
112
Encoder (Pulse Train Input) Related Settings
You can achieve speed control or simple positioning control by using pulse train input.
Following table shows the related parameters of those function. Please refer to chapter
4 for the detailed description.
“P” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units
[EA] terminal selection
Three option codes:
…Speed reference (incl. PID)
…For control with encoder
feedback
…Extended terminal for EzSQ
00
Pulse train input mode
selection for feedback
Four option codes:
…Single-phase pulse [EA]
…2-phase pulse (90
difference)
1 ([EA] and [EB])
…2-phase pulse (90
difference)
2 ([EA] and [EB])
…Single-phase pulse [EA] and
direction signal [EB]
00
Encoder pulse setting
Sets the pulse number (ppr) of the
encoder, set range is 32~1024
pulses
512.
Simple positioning
selection
Two option codes:
…simple positioning
deactivated
…simple positioning activated
00
Creep Speed
Set range is start frequency (
)
~10.00 Hz
5.00
Hz
Over-speed error
detection level
Set range is 0~150%
115.0
%
Speed deviation error
detection level
Set range is 0~120 Hz
10.00
Hz
Speed control Related Settings
Set "
" in
and "
" in
, then output frequency is controlled by single phase
pulse train input to EA terminal.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......