3
38
Accel/Decel
Standard acceleration and deceleration is
linear. The inverter CPU can also
calculate an S-curve acceleration or
deceleration curve as shown. This profile
is useful for favoring the load
characteristics in particular applications.
Curve settings for acceleration and
deceleration are independently selected.
To enable the S-curve, use function
(acceleration) and
(deceleration).
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units
Acceleration curve selection
Set the characteristic curve of
Acc1 and Acc2, five options:
linear
S-curve
U-curve
Inverse U-curve
EL S-curve
Set the characteristic curve of
Dec1 and Dec2, options are
same as above (
)
01
Deceleration curve selection
01
Acceleration curve constant
Range is 01 to 10.
Range is 01 to 10.
02
Deceleration curve constant
02
Curvature of EL-S-curve at
the start of acceleration
Range is 0 to 50%
10.
%
Curvature of EL-S-curve at
the end of acceleration
Range is 0 to 50%
10.
%
Curvature of EL-S-curve at
the start of deceleration
Range is 0 to 50%
10.
%
Curvature of EL-S-curve at
the end of deceleration
Range is 0 to 50%
10.
%
See next page for the details.
=
Accel. curve selection
Output
frequency
S-curve
Linear
t
0
=
Target
freq.
Acceleration period
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......