C
−
−
−
−
17
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
A B Initial data Units
b046
Reverse run protection
Two option codes:
00
…
No protection
01
…
Reverse rotation is protected
00
−
b049
Dual Rating Selection
00
…
(CT mode) /
01
…
(VT mode)
00
B050
Controlled deceleration on
power loss
Four option codes:
00
…
Trips
01
…
Decelerates to a stop
02
…
Decelerates to a stop with DC
bus voltage controlled
03
…
Decelerates to a stop with DC
bus voltage controlled, then
restart
00
−
B051
DC bus voltage trigger level
of ctrl. decel.
Setting of DC bus voltage to start
controlled decel. operation. Range
is 0.0 to 1000.0
220.0/
440.0
V
B052
Over-voltage threshold of
ctrl. decel.
Setting the OV-LAD stop level of
controlled decel. operation. Range
is 0.0 to 1000.0
360.0/
720.0
V
B053
Deceleration time of ctrl.
decel.
Range is 0.01 to 3600.0
1.00
sec
B054
Initial freq. drop of ctrl.
decel.
Setting of initial freq. drop.
Range is 0.0 to 10.0 Hz
0.00
Hz
B060
Maximum-limit level of
window comparator (O)
Set range, {Min.-limit level (
b061
)
+ hysteresis width (
b062
)x2} to
100 %
(Minimum of 0%)
100.
%
B061
Minimum-limit level of
window comparator (O)
Set range, 0 to {Max.-limit level
(
b060
) - hysteresis width
(
b062
)x2} % (Maximum of 0%)
0.
%
B062
Hysteresis width of window
comparator (O)
Set range, 0 to {Max.-limit level
(
b060
) - Min.-limit level (
b061
)}/2 %
(Maximum of 10%)
0.
%
B063
Maximum-limit level of
window comparator (OI)
Set range, {Min.-limit level (
b064
+
hysteresis width (
b065
)x2} to
100 %
(Minimum of 0%)
100.
%
B064
Minimum-limit level of
window comparator (OI)
Set range, 0 to {Max.-limit level
(
b063
) - hysteresis width
(
b065
)x2} % (Maximum of 0%)
0.
%
b065
Hysteresis width of window
comparator (OI)
Set range, 0 to {Max.-limit level
(
b063
) - Min.-limit level (
b064
)}/2 %
(Maximum of 10%)
0.
%
b070
Operation level at O
disconnection
Set range, 0 to 100%, or “no”
(ignore)
no
-
b071
Operation level at OI
disconnection
Set range, 0 to 100%, or “no”
(ignore)
no
-
b075
Ambient temperature setting Set range is,
-10~50
°
C
40
°
C
B078
Watt-hour clearance
Two option codes:
00
…
OFF
01
…
ON (press STR then clear)
00
-
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......