background image

Translation of the original instructions

1

About this document

This document describes the use of the above-mentioned product.

1.1

Further applicable documents

Operating instructions for proximity sensor

Assembly instructions for connecting cable

Assembly instructions for adapter kit

Certification documents

Operating conditions for explosion protection

 All available documents for the product 

è

 www.festo.com/pk.

2

Safety

2.1

General safety instructions

Only use the product in original status without unauthorised modifications.

Only use the product if it is in perfect technical condition.

Use only proximity sensors approved for the product.

Take into consideration the ambient conditions at the location of use.

Observe labelling on the product.

Operating medium

Only use compressed air in accordance with the specifications

è

 15 Technical data.

Use only unlubricated compressed air under normal conditions. Once the
product has been used with lubricated compressed air, it must continue to be
operated with lubricated compressed air only.

Return to Festo

Hazardous substances can endanger the health and safety of personnel and
cause damage to the environment. To prevent hazards, the product should only
be returned upon explicit request by Festo.

Consult your regional Festo contact. 

Complete the declaration of contamination and attach it to the outside of the
packaging. 

Comply with all legal requirements for the handling of hazardous substances
and the transport of dangerous goods. 

2.2

Intended use

The linear drive DFPI-...-E-NB3... is intended for regulation in process systems. It is
particularly appropriate for pneumatic positioning under harsh operating condi-
tions.

2.3

Target group

The document is targeted towards individuals who mount and operate the
product. It is additionally targeted towards individuals who are entrusted with the
planning and application of the product in a safety-oriented system.

3

Further information

Accessories 

è

 www.festo.com/catalogue.

Spare parts 

è

www.festo.com/spareparts.

4

Service

Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

5

Product overview

5.1

Product design

The linear drive consists of a double-acting pneumatic cylinder with integrated
displacement encoder. For mounting, the linear drive has a mounting interface in
accordance with ISO 15552 at the bearing cap and the connection cap.

5.1.1

Design of DFPI-...-ND2P-E-NB3P

1 Housing

2 Air duct

3 Earth terminal

4 Mounting interface in accordance

with ISO 15552

5 Mounting kit interface for external

positioner

6 Retaining screw for cover

7 Retaining screw for housing

8 Electrical and pneumatic connec-

tion (under the protective cap)

9 Piston rod with mounting thread

for accessories

10 Spanner flat

11 Bearing cap

12 Tie rod

13 End cap

Fig. 1 DFPI-100-...-ND2P-E-NB3P

8088101

DFPI-...-ND2P-E-NB3

Linear drive

8088101
2018-04c
[8088103]

Instructions | Operating

Festo AG & Co. KG 
Ruiter Straße 82 
73734 Esslingen 
Germany
+49 711 347-0 

www.festo.com 

Summary of Contents for DFPI-xxx-ND2P-E-NB3 Series

Page 1: ...h all legal requirements for the handling of hazardous substances and the transport of dangerous goods 2 2 Intended use The linear drive DFPI E NB3 is intended for regulation in process systems It is particularly appropriate for pneumatic positioning under harsh operating condi tions 2 3 Target group The document is targeted towards individuals who mount and operate the product It is additionally ...

Page 2: ...0 320 250 Tab 1 When using additional proximity sensors NOTICE When linear drives are installed too close to each other the cylinder magnet can disturb the proximity sensor on the adjacent linear drive 1 Mount sensor bracket on the tie rod Tightening torque 0 6 1 Nm 2 Mount the proximity sensors è 1 1 Further applicable documents 3 Check minimum distances to ferritic and magnetic materials Place t...

Page 3: ...Fig 1 6 2 Disconnect the pre assembled plug at the electrical connection 3 Select appropriate electrical connecting cable At least 3 wire with cable end sleeves Outside diameter 4 5 10 mm Conductor cross section 0 75 1 5 mm 4 Guide the electrical connecting cable through the M16 cable connector 5 Tighten the cable connector Tightening torque 10 Nm 6 Wire the plug è Tab 4 and mount on the electrica...

Page 4: ...d DFPI P9 Cable connector M16x1 5 3 pin straight plug screw terminal Pneumatic connection DFPI P For tubing O D 8 mm DFPI P9 M12 Air connection Gy Operating pressure bar 3 8 Nominal operating pressure bar 6 Operating medium Compressed air to ISO 8573 1 2010 7 4 4 Note on the operating medi um Lubricated operation possible in which case lubricated operation will always be required Degree of protect...

Reviews: