Ver.2
58
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
A
B
Initial data
Units
Current level of active freq.
matching
Sets the current level of active freq.
matching restart, range is 0.1*inverter
rated current to 2.0*inverter rated
current, resolution 0.1 seconds.
Rated
current
A
Deceleration rate of active
freq. matching
Sets the deceleration rate when active
freq. matching restart, range is 0.1 to
3000.0, resolution 0.1 seconds.
0.5
s
Start freq. of active freq.
matching
Three option codes:
freq at previous shutoff
start from max. Hz
start from set frequency
00
Software lock mode selection Prevents parameter changes, in five
options, option codes:
all parameters except
are locked
when [SFT] terminal is ON
all parameters except
and
output frequency
are locked
when [SFT] terminal is ON
all parameters except
are
locked
all parameters except
and
output frequency
are locked
High level access including
See appendix C for the accessible
parameters in this mode.
01
Motor cable length
parameter
Set range is 5 to 20.
10.
Run/power ON warning time Range is,
.:Warning disabled
. to
.:
10~99,990 hrs (unit: 10)
to
:
100,000~655,350 hrs (unit: 100)
0.
Hrs.
Rotation direction restriction Three option codes:
No restriction
Reverse rotation is restricted
Forward rotation is restricted
00
Reduced voltage start
selection
Set range,
(disabling the function),
(approx. 6ms) to
(approx. 1.5s)
2
Function code display
restriction
Six option codes:
Full display
Function-specific display
User setting (and
)
Data comparison display
Basic display
Monitor display only
00
Initial display selection
Func. code that SET key pressed
last displayed.(*)
~
~
displayed
displayed
B display of LCD operator
001
Automatic user parameter
registration
Two option codes:
Disable
Enable
00
Torque limit selection
Three option codes:
Quadrant-specific setting mode
Terminal-switching mode
Analog voltage input mode(O)
00
Torque limit 1 (fwd/power)
Torque limit level in forward powering
quadrant, range is 0 to 200%/no(disabled)
200
%
Torque limit 2 (fwd/power)
Torque limit level in forward powering
quadrant, range is 0 to 200%/no(disabled)
200
%
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......