Output Function Summary Table
–
This table shows all functions for the logical outputs
(terminals [11], [12] and [AL]) at a glance. Detailed descriptions of these functions,
related parameters and settings, and example wiring diagrams are in “Using Intelligent
Output Terminals” in chapter 4.
Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
RUN
Run Signal
ON
When the inverter is in Run Mode
OFF
When the inverter is in Stop Mode
FA1
Frequency Arrival Type
1
–Constant Speed
ON
When output to motor is at the set frequency
OFF
When output to motor is OFF, or in any acceleration
or deceleration ramp
FA2
Frequency Arrival Type
2
–Over frequency
ON
When output to motor is at or above the set freq.,
even if in accel (
) or decel (
) ramps
OFF
When output to motor is OFF, or at a level below the
set frequency
OL
Overload Advance
Notice Signal 1
ON
When output current is more than the set threshold
(
) for the overload signal
OFF
When output current is less than the set threshold
for the deviation signal
OD
Output Deviation for PID
Control
ON
When PID error is more than the set threshold for
the deviation signal
OFF
When PID error is less than the set threshold for the
deviation signal
AL
Alarm Signal
ON
When an alarm signal has occurred and has not
been cleared
OFF
When no alarm has occurred since the last cleaning
of alarm(s)
FA3
Frequency Arrival Type
3
–Set frequency
ON
When output to motor is at the set frequency, during
accel (
) and decel (
).
OFF
When output to motor is OFF, or is not at a level of
the set frequency
OTQ
Over/under Torque
Signal
ON
Estimated motor torque exceeds the specified level
OFF
Estimated motor torque is lower than the specified
level
UV
Undervoltage
ON
Inverter is in Undervoltage
OFF
Inverter is not in Undervoltage
TRQ
Torque Limited Signal
ON
Torque limit function is executing
OFF
Torque limit function is not executing
RNT
Run Time Expired
ON
Total running time of the inverter exceeds the
specified value
OFF
Total running time of the inverter does not exceed
the specified value
ONT
Power ON time Expired
ON
Total power ON time of the inverter exceeds the
specified value
OFF
Total power ON time of the inverter does not exceed
the specified value
THM
Thermal Warning
ON
Accumulated thermal count exceeds the
set
value
OFF
Accumulated thermal count does not exceed the
set value
BRK
Brake Release Signal
ON
Output for brake release
OFF
No action for brake
BER
Brake Error Signal
ON
Brake error has occurred
OFF
Brake performance is normal
ZS
Zero Hz Speed
Detection Signal
ON
Output frequency falls below the threshold specified
in
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......