Ver.2
68
OFF
Inverter is in Stop Mode, motor stops
RV
Reverse Run/Stop
ON
Inverter is in Run Mode, motor runs reverse
OFF
Inverter is in Stop Mode, motor stops
CF1 *1
Multi-speed Select,
Bit 0 (LSB)
ON
Binary encoded speed select, Bit 0, logical 1
OFF
Binary encoded speed select, Bit 0, logical 0
CF2
Multi-speed Select,
Bit 1
ON
Binary encoded speed select, Bit 1, logical 1
OFF
Binary encoded speed select, Bit 1, logical 0
CF3
Multi-speed Select,
Bit 2
ON
Binary encoded speed select, Bit 2, logical 1
OFF
Binary encoded speed select, Bit 2, logical 0
CF4
Multi-speed Select,
Bit 3 (MSB)
ON
Binary encoded speed select, Bit 3, logical 1
OFF
Binary encoded speed select, Bit 3, logical 0
JG
Jogging
ON
Inverter is in Run Mode, output to motor runs at jog
parameter frequency
OFF
Inverter is in Stop Mode
DB
External DC braking
ON
DC braking will be applied during deceleration
OFF
DC braking will not be applied
SET
Set (select) 2nd Motor
Data
ON
The inverter uses 2nd motor parameters for generating
frequency output to motor
OFF
The inverter uses 1st (main) motor parameters for
generating frequency output to motor
2CH
2-stage Acceleration
and Deceleration
ON
Frequency output uses 2nd-stage acceleration and
deceleration values
OFF
Frequency output uses standard acceleration and
deceleration values
FRS
Free-run Stop
ON
Causes output to turn OFF, allowing motor to free run
(coast) to stop
OFF
Output operates normally, so controlled deceleration stop
motor
EXT
External Trip
ON
When assigned input transitions OFF to ON, inverter
latches trip event and displays
OFF
No trip event for ON to OFF, any recorded trip events
remain in history until reset
USP
Unattended Start
Protection
ON
On power up, the inverter will not resume a Run command
(mostly used in the US)
OFF
On power up, the inverter will resume a Run command that
was active before power loss
CS
Commercial
power
source switchover
ON
Motor can be driven by commercial power
OFF
Motor is driven via the inverter
SFT
Software Lock
ON
The keypad and remote programming devices are prevented
from changing parameters
OFF
The parameters may be edited and stored
AT
Analog Input
Voltage/Current Select
ON
Refer to “Analog Input Settings” on page 3-13.
OFF
RS
Reset Inverter
ON
The trip condition is reset, the motor output is turned OFF,
and power up reset is asserted
OFF
Normal power-ON operation
PTC
PTC
thermistor
Thermal Protection
(C005 only)
ANLG
When a thermistor is connected to terminal [5] and [L], the
inverter checks for over-temperature and will cause trip
event and turn OFF output to motor
OPEN
A disconnect of the thermistor causes a trip event, and the
inverter turns OFF the motor
Input Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
STA
Start
(3-wire interface)
ON
Starts the motor rotation
OFF
No change to present motor status
STP
Stop
(3-wire interface)
ON
Stops the motor rotation
OFF
No change to present motor status
F/R
FWD, REV
(3-wire interface)
ON
Selects the direction of motor rotation: ON = FWD. While the
motor is rotating, a change of F/R will start a deceleration,
followed by a change in direction
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......