Ver.3
−
−
−
−
129
““““b
b
b
b”””” Function
Function
Function
Function
A
A
A
A
B
B
B
B
D
D
D
Defaults
efaults
efaults
efaults
Func.
Func.
Func.
Func.
Code
Code
Code
Code
N
N
N
Name
ame
ame
ame
D
D
D
Description
escription
escription
escription
Initial data
Initial data
Initial data
Initial data
Units
Units
Units
Units
b
b
b
b0
0
0
01
1
1
15
5
5
5
Free setting
electronic
thermal ~freq.1
Range is 0 to 400(580)
*1
Hz
0.
Hz
b
b
b
b0
0
0
01
1
1
16
6
6
6
Free setting
electronic
thermal
~current1
Range is 0 to inverter rated current Amps
0.00
Amps
b
b
b
b0
0
0
01
1
1
17
7
7
7
Free setting
electronic
thermal ~freq.2
Range is 0 to 400(580)
*1
Hz
0.
Hz
b
b
b
b0
0
0
01
1
1
18
8
8
8
Free setting
electronic
thermal
~current2
Range is 0 to inverter rated current Amps
0.00
Amps
b
b
b
b0
0
0
01
1
1
19
9
9
9
Free setting
electronic
thermal ~freq.3
Range is 0 to 400(580)
*1
Hz
0.
Hz
b
b
b
b0
0
0
02
2
2
20
0
0
0
Free setting
electronic
thermal
~current3
Range is 0 to inverter rated current Amps
0.00
Amps
b
b
b
b0
0
0
02
2
2
21
1
1
1
Overload
restriction
operation mode
Select the operation mode during overload conditions, four
options, option codes:
00
00
00
00
…
Disabled
0
0
0
01
1
1
1
…
Enabled for acceleration and constant speed
0
0
0
02
2
2
2
…
Enabled for constant speed only
0
0
0
03
3
3
3
…
Enabled for acceleration and constant speed, increase speed
at regen.
01
−
b
b
b
b22
22
22
221
1
1
1
Overload
restriction
operation mode,
2
nd
motor
01
−
b
b
b
b0
0
0
022
22
22
22
Overload
restriction level
Sets the level of overload restriction, between 20% and 200% of
the rated current of the inverter, setting resolution is 1% of
rated current
Rated
current
x 1.5
Amps
b
b
b
b222
222
222
222
Overload
restriction level,
2
nd
motor
Rated
current
x 1.5
Amps
b
b
b
b0
0
0
023
23
23
23
Deceleration rate
at overload
restriction
Sets the deceleration rate when inverter detects overload, range
is 0.1 to 3000.0, resolution 0.1
1.0
s
b
b
b
b223
223
223
223
Deceleration rate
at overload
restriction, 2
nd
motor
1.0
s
b
b
b
b0
0
0
024
24
24
24
Overload
restriction
operation mode 2
Select the operation mode during overload conditions, four
options, option codes:
00
00
00
00
…
Disabled
0
0
0
01
1
1
1
…
Enabled for acceleration and constant speed
0
0
0
02
2
2
2
…
Enabled for constant speed only
0
0
0
03
3
3
3
…
Enabled for acceleration and constant speed, increase speed
at regen.
01
−
b
b
b
b0
0
0
025
25
25
25
Overload
restriction level 2
Sets the level of overload restriction, between 20% and 200% of
the rated current of the inverter, setting resolution is 1% of
rated current
Rated
current
x 1.5
%
b
b
b
b0
0
0
02
2
2
26
6
6
6
Deceleration rate
2 at overload
restriction
Sets the deceleration rate when inverter detects overload, range
is 0.1 to 3000.0, resolution 0.1
1.0
s
b
b
b
b0
0
0
02
2
2
27
7
7
7
OC suppression
selection
Two option codes:
00
00
00
00
…
Disabled
0
0
0
01
1
1
1
…
Enabled without voltage reduction
0
0
0
02
2
2
2...Enable with voltage reduction
00
−
b
b
b
b0
0
0
02
2
2
28
8
8
8
Current level of
active freq.
matching
Sets the current level of active freq. matching restart, range is
0.1*inverter rated current to 2.0*inverter rated current,
resolution 0.1
Rated
current
A
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......