4
18
While using the multi-speed capability, you can monitor the present frequency with
monitor function
during each segment of a multi-speed operation.
NOTE: When using the Multi-speed Select settings CF1 to CF4, do not display
parameter F001 or change the value of
while the inverter is in Run Mode (motor
running). If it is necessary to check the value of
during Run Mode, please monitor
instead of
.
There are two ways to program the speeds into the registers
to
:
1. Standard keypad programming:
a. Select each parameter
to
.
b. Press the SET key to view the parameter value.
c. Use the
and
keys to edit the value.
d. Use the SET key to save the data to memory.
2. Programming using the CF switches. Set the speed by following these steps:
a. Turn the Run command OFF (Stop Mode).
b. Turn inputs ON to select desired Multi-speed. Display the value of
on the
digital operator.
c. Set the desired output frequency by pressing the
and
keys.
d. Press the SET key once to store the set frequency. When this occurs,
indicates the output frequency of Multi-speed n.
e. Press the SET key once to confirm that the indication is the same as the set
frequency.
f. Repeat operations in 2. a) to 2. e) to set the frequency of other Multi-speeds. It
can be set also by parameters
to
in the first procedure 1. a) to 1. d).
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......