Ver.3
−
−
−
−
125
““““A
A
A
A”””” Function
Function
Function
Function
A
A
A
A
B
B
B
B
D
D
D
Defaults
efaults
efaults
efaults
Func.
Func.
Func.
Func.
Code
Code
Code
Code
N
N
N
Name
ame
ame
ame
D
D
D
Description
escription
escription
escription
Initial data
Initial data
Initial data
Initial data
Units
Units
Units
Units
A
A
A
A0
0
0
079
79
79
79
PID feed forward selection
Selects source of feed forward
gain, option codes:
00
00
00
00
…
Disabled
0
0
0
01
1
1
1
…
[O] terminal (voltage in)
0
0
0
02
2
2
2
…
[OI] terminal (current in)
00
−
A
A
A
A0
0
0
08
8
8
81
1
1
1
AVR function select
Automatic (output) voltage
regulation, selects from three type
of AVR functions, three option
codes:
00
00
00
00
…
AVR enabled
0
0
0
01
1
1
1
…
AVR disabled
0
0
0
02
2
2
2
…
AVR enabled except during
deceleration
02
−
A
A
A
A2
2
2
28
8
8
81
1
1
1
AVR function select,
2
nd
motor
02
−
A
A
A
A0
0
0
08
8
8
82
2
2
2
AVR voltage select
200V class inverter settings:
……
200/215/220/230/240
400V class inverter settings:
……
380/400/415/440/460/480
230/
400
V
A
A
A
A2
2
2
28
8
8
82
2
2
2
AVR voltage select,
2
nd
motor
230/
400
V
A
A
A
A0
0
0
08
8
8
83
3
3
3
AVR filter time constant
Define the time constant of the
AVR filter, range is 0.000 to 10.00
sec.
0.300
s
A
A
A
A0
0
0
08
8
8
84
4
4
4
AVR deceleration gain
Gain adjustment of the braking
performance, range is 50. to 200.%
100.
%
A
A
A
A0
0
0
08
8
8
85
5
5
5
Energy-saving operation
mode
Two option codes:
00
00
00
00
…
Normal operation
0
0
0
01
1
1
1
…
Energy-saving operation
00
−
A
A
A
A0
0
0
086
86
86
86
Energy-saving mode tuning Range is 0.0 to 100.0 %.
50.0
%
A
A
A
A0
0
0
09
9
9
92
2
2
2
Acceleration time (2)
Duration of 2
nd
segment of
acceleration, range is:
0.00 to 3600 sec.
10.00
s
A
A
A
A2
2
2
29
9
9
92
2
2
2
Acceleration time (2),
2
nd
motor
10.00
s
A
A
A
A0
0
0
09
9
9
93
3
3
3
Deceleration time (2)
Duration of 2
nd
segment of
deceleration, range is:
0.00 to 3600 sec.
10.00
s
A
A
A
A2
2
2
29
9
9
93
3
3
3
Deceleration time (2),
2
nd
motor
10.00
s
A
A
A
A0
0
0
09
9
9
94
4
4
4
Select method to switch to
Acc2/Dec2 profile
Three options for switching from
1st to 2nd accel/decel:
00
00
00
00
…
2CH input from terminal
0
0
0
01
1
1
1
…
Transition frequency
0
0
0
02
2
2
2
…
Forward and reverse
00
−
A
A
A
A2
2
2
29
9
9
94
4
4
4
Select method to switch to
Acc2/Dec2 profile, 2
nd
motor
00
−
A
A
A
A0
0
0
09
9
9
95
5
5
5
Acc1 to Acc2 frequency
transition point
Output frequency at which Accel1
switches to Accel2, range is 0.00 to
400.0(580.0)
*1
Hz
0.00
Hz
A
A
A
A2
2
2
29
9
9
95
5
5
5
Acc1 to Acc2 frequency
transition point, 2
nd
motor
0.00
Hz
A
A
A
A0
0
0
096
96
96
96
Dec1 to Dec2 frequency
transition point
Output frequency at which Decel1
switches to Decel2, range is 0.00 to
400.0(580.0)
*1
Hz
0.00
Hz
A
A
A
A2
2
2
296
96
96
96
Dec1 to Dec2 frequency
transition point, 2
nd
motor
0.00
Hz
A
A
A
A0
0
0
097
97
97
97
Acceleration curve selection Set the characteristic curve of
Acc1 and Acc2, five options:
00
00
00
00
…
linear
0
0
0
01
1
1
1
…
S-curve
0
0
0
02
2
2
2
…
U-curve
0
0
0
03
3
3
3
…
Inverse U-curve
0
0
0
04
4
4
4
…
EL S-curve
01
−
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......